UE44x7 Safety Remote Controller

28-Nov-2007

UE44x7 Safety Remote Controller

 

 

• First IP 67 safety controller
• Stand-alone or network operation possible
• Super-rapid adjustable reaction time (8 ms)
• Standard PLC can control safety applications

The first compact safety controller in IP67 technology allows remote safety automation directly in situ without a control cabinet. It has three unique functions:
• Stand-alone operation – without any further safety controller. Can also operate within a combined network.
• Fast Shut-off function – extremely rapid and fixed reaction times (8 ms), regardless of whether stand-alone or in a combined network. For minimising safety distances between the safety equipment and the hazardous point-of-operation.
• Reasonably priced safety solution with Safety Enable – standard PLCs control the safety outputs of the UE44x7, no further safety controller necessary.

Applications
• Emergency stop switch:
• Safety switches:
• Non-contact safety switches:
• Opto-electronic protective devices:
• Two-hand control systems:
• Control switches with lamp:
• Operating mode selector switch:
• Muting sensors:
• Muting lamp:

Functions
• Usage of the expanded functions on the SDL:
• External device monitoring:
• Restart interlock:
• Automatic Reset:
• Logical functions: AND, NOT, OR, XNOR, XOR
• On-delay:
• Off-delay:
• Door monitoring:
• Signal routing:
• Bidirectional communication:

Technical data

Fieldbus: DeviceNet Safety
Enclosure rating: IP 67
Ambient operating temperature from ... to: -10 ... 55 °C
Protection class: III (IEC 61131-2)
Weight: 650 g
Category: 4 (EN 954-1)
Safety integrity level: 19.2 ... 28.8 V DC
Maximum power consumption: 4 A, Class 2, per connection
Connection type supply voltage: Mini 7/8" × 4
Number of safety inputs: 6 dual-channel resp. 12 single-channel
Input voltage HIGH field signal inputs: 11 ... 30 V DC
Input delay field signal inputs: configurable 0 ... 635 ms
Number of test-/signal outputs
(with current monitoring): 12
Type of output test-/signal outputs: PNP semiconductor
Output current test-/signal outputs: 700 mA
Number of safe outputs: 2 dual-channel
Type of output safety capable outputs: Bipolar type
Maximum switching current safety capable
outputs: 2 A
Number of SDL connections: 2
Maximum number of safety target connections: 6
DeviceNet communication rate:

125 KBit/s, 250 KBit/s, 500 KBit/s,
Autobaud Detection

Connection type DeviceNet: Mini 7/8" × 5
System part: Safety network solutions

 

 

 

 

Courtesy of  SICK