• First IP 67 safety controller
• Stand-alone or network operation possible
• Super-rapid adjustable reaction time (8 ms)
• Standard PLC can control safety applications
The first compact safety controller in IP67 technology allows remote safety automation directly in situ without a control cabinet. It has three unique functions:
• Stand-alone operation – without any further safety controller. Can also operate within a combined network.
• Fast Shut-off function – extremely rapid and fixed reaction times (8 ms), regardless of whether stand-alone or in a combined network. For minimising safety distances between the safety equipment and the hazardous point-of-operation.
• Reasonably priced safety solution with Safety Enable – standard PLCs control the safety outputs of the UE44x7, no further safety controller necessary.
Applications
• Emergency stop switch:
• Safety switches:
• Non-contact safety switches:
• Opto-electronic protective devices:
• Two-hand control systems:
• Control switches with lamp:
• Operating mode selector switch:
• Muting sensors:
• Muting lamp:
Functions
• Usage of the expanded functions on the SDL:
• External device monitoring:
• Restart interlock:
• Automatic Reset:
• Logical functions: AND, NOT, OR, XNOR, XOR
• On-delay:
• Off-delay:
• Door monitoring:
• Signal routing:
• Bidirectional communication:
Technical data
|
Fieldbus: |
DeviceNet Safety |
|
Enclosure rating: |
IP 67 |
|
Ambient operating temperature from ... to: |
-10 ... 55 °C |
|
Protection class: |
III (IEC 61131-2) |
|
Weight: |
650 g |
|
Category: |
4 (EN 954-1) |
|
Safety integrity level: |
19.2 ... 28.8 V DC |
|
Maximum power consumption: |
4 A, Class 2, per connection |
|
Connection type supply voltage: |
Mini 7/8" × 4 |
|
Number of safety inputs: |
6 dual-channel resp. 12 single-channel |
|
Input voltage HIGH field signal inputs: |
11 ... 30 V DC |
|
Input delay field signal inputs: |
configurable 0 ... 635 ms |
|
Number of test-/signal outputs |
|
(with current monitoring): |
12 |
|
Type of output test-/signal outputs: |
PNP semiconductor |
|
Output current test-/signal outputs: |
700 mA |
|
Number of safe outputs: |
2 dual-channel |
|
Type of output safety capable outputs: |
Bipolar type |
|
Maximum switching current safety capable |
|
outputs: |
2 A |
|
Number of SDL connections: |
2 |
|
Maximum number of safety target connections: |
6 |
|
DeviceNet communication rate: |
125 KBit/s, 250 KBit/s, 500 KBit/s,
Autobaud Detection
|
|
Connection type DeviceNet: |
Mini 7/8" × 5 |
|
System part: |
Safety network solutions |
Courtesy of SICK
|